Ademco #93 Menu (Under Construction)

"ZONE PROG?" 0 = No for next menu (Expert Mode)
1 = Yes enter Zone Programming
Display Options
1. "Set to Confirm?" Enter 1 = Yes, 0 = No then * to continue
2. "Enter Zone Number" Enter 3-digit zone number then *, 000 exits
Regualar Zones
Relay Zones
ECP Device Supervisory Zones
Bell 1 Supervision
Bell 2 Supervision
Earth Ground Supervision
AUX Input Supervision
Dialer Line 1 Supervision
Dialer Line 2 Supervision
AUX Relay
LORRA Triggers
Secondary RF Receiver Sup.
Primary RF Receiver Supervision
Duress Report Code
Keypad Fire (* & 1)
Keypad Medical (# & 3)
Polling Loop Short
Keypad Police (* & #)
001 - 128 (001 to 032 on 32FB)
601 - 632 (601 to 616 on 32FB)
800 - 830 (Address 00 to 30)
970
971
972
973
974
975
976
977
988
990
992
995
996
997
999
3. Display shows current settings Press * to move to next, # for previous
4. "Zone Response" Enter Zone Type then *, # for previous
00 = Zone Disabled/Deleted
01 = Delay Zone
02 = Secondary Delay Zone
03 = Perimeter/Instant
04 = Interior Follower/Motions
05 = Trouble by Day/alarm by Night
06 = 24 hour Silent
07 = 24 hour Police Panic
08 = 24 hour Aux/Medical
09 = Fire w/o Verification
10 = Interior Delay
16 = Fire w/ Verification
17 = Waterflow
18 = Fire Supervisory
19 = 24-Hour Trouble
20 = Arm-Stay
21 = Arm-Away
22 = Disarm
23 = No Alarm Response
27 = Access Point
28 = MLB Supervision (Main logic board) (Gateway Module)
29 = Momentary Exit (used with VistaKey Module)
5. "Partition" Enter 1 to 8 for Partition 1 to 8 then *, # for previous (1 or 2 for 32FB)
6. "Report Code" Enter 10 then *, # for previous
7. "Input Type" Enter Sensor Type then *, # for previous
00 = Not Used
01 = Hardwire
03 = Supervised RF
04 = Unsupervised RF
05 = Button Type RF (Keyfob)
06 = Serial Polling Loop Device
07 = Dip Switch Polling Loop Device
08 = Polling Right Loop
09 = Console Input (Code + #73)
10 = Passpoint Access Control (ACS)
11 = Vista-key DSM (Door Status Monitor)
12 = Vista-key RTE
13 = Vista-key general purpose
8. "BELL/RLY SEL" Select Bell/aUX relay for zone then *, # for previous
0 = None
1 = Bell 1
2 = Bell 2
3 = Bell 1 & Bell 2
4 = AUX Relay
5 = Bell 1 & AUX Relay
6 = Bell 2 & AUX Relay
7 = Bell 1 & Bell 2 & AUX Relay
9. "INPUT S/N" Trip sensor twice to learn serial or manually enter serial and loop then *, # for previous
10. Display shows current settings Press * to move to next, # for previous





"EXPERT MODE?" 0 = No for next menu (Report Code Programming)
1 = Yes enter Expert Mode
Display
"SET TO CONFIRM?" 1 = Yes, 0 = No, Press * to move to next, # for previous
Zn
001
ZT
03
P
1
RC
10
In
HW
L
--
Summary of zone 1's current programming.
Enter 3-digit zone number and press *, 000 to quit
Zn
010
ZT
03
P
1
RC
10
In
RF
L
1s
Enter zone information and then * for next, # for previous (A moves right, B moves left)
ZT
P
RC
In
L
= Zone Type
= Partition
= Report Code
= Input Device Type
= Loop number
Zn
010
B
2
M
1
V
1
AC
01
E
1
AD
01
Enter zone information and then * for next, # for previous (A moves right, B moves left)
B
M
V
AC
E
AD
= Bell/Relay Assignment
= Maintenance (only used if In = 3, 6)
= V-plex Relay (only used if In = 6)
= Access Point (only used if ZT = 27, 29 or In = 6, 11, 12, 13)
= Entry or Exit (only used if ZT = 27)
= Address (If In = 9 enter Device address, if In = 10 enter PassPoint Zone)
"INPUT S/N" Trip sensor twice to learn serial or manually enter serial and loop then *, # for previous





"REPORT CODE PROG"
1 = YES 0 = NO
0 = No for next menu (Alpha Programming)
1 = Yes enter Report Code Programming
ALARM, ID DIGIT?
1 = YES 0 = NO
Press 1 to enter Alarm Report Codes for zones.
Press 0 to skip to the next main menu option. (RESTR, SUPV. CODES)
ENTER ZONE NO.
000 = QUIT 001
Enter the zone number for which you are entering the report code.
Press * to continue.
001 REPORT CODE
1st 00 2nd 00 00
Enter the first digit of the Alarm report code (double-digit entry) and press *. Enter the 2nd digit of the
Alarm Report code. Press * to continue.
ENTER ZONE NO.
000 = QUIT 001
Enter the zone number for which you are entering the report code. When all zone Alarm Codes have been
programmed, enter 000 to Quit. Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.
RESTR, SUPV. CODE
1 = YES 0 = NO
Press 1 to enter Restore and Supervisory Codes for zones.
Press 0 to skip to the next main menu option. (SYSTEM GROUP #1)
ENTER ZN FOR GRP
000 = QUIT 001
Enter one zone for each group of 16 zones (001-016, 017-032, etc.).
ALARM RESTORE
GRP 001-016 00
Enter an Alarm Restore Report Code for this group of zones (double-digit entry).
Press * to continue.
TROUBLE
GRP 001-016 00
Enter a Trouble Report Code for this group of zones (double-digit entry).
Press * to continue.
TROUBLE RESTORE
GRP 001-016 00
Enter a Trouble Restore Report Code for this group of zones (double-digit entry).
Press * to continue.
BYPASS
GRP 001-016 00
Enter a Bypass Report Code for this group of zones (double-digit entry).
Press * to continue.
BYPASS RESTORE
GRP 001-016 00
Enter a Bypass Restore Report Code for this group of zones (double-digit entry).
Press * to continue.
ENTER ZN FOR GRP
000 = QUIT 017
Enter one zone for each group of 16 zones. When you are finished entering Restore and Supervisory Codes
for all zone groups, enter 000. Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.
SYSTEM GROUP #1?
1 = YES 0 = NO
To enter System Group #1 codes, press 1.
Press 0 to skip to the next main menu option. (SYSTEM GROUP #2)
CLOSE
1st 00 2nd 00
Enter the first digit of the Closing (Arm-AWAY) report. Press *. Enter the second digit of the report.
Press * to continue.
OPEN
1st 00 2nd 00
Enter the first digit of the Opening (Disarm) report. Press *. Enter the second digit of the report.
Press * to continue. (This also enables the "Callback Requested report")
LOW BATTERY
1st 00 2nd 00
Enter the first digit of the System Low Battery report. Press *. Enter the second digit of the report.
Press * to continue.
LOW BATT RESTR
1st 00 2nd 00
Enter the first digit of the System Low Battery Restore report. Press *. Enter the second digit of the report.
Press * to continue.
AC LOSS
1st 00 2nd 00
Enter the first digit of the System AC Loss report. Press *. Enter the second digit of the report.
Press * to continue.
AC RESTORE
1st 00 2nd 00
Enter the first digit of the System AC Restore report. Press *. Enter the second digit of the report.
Press * to continue.
TEST
1st 00 2nd 00
Enter the first digit of the System Test report. Press *. Enter the second digit of the report.
Press * to continue.
POWER UP
1st 00 2nd 00
Enter the first digit of the System Power-Up report. Press *. Enter the second digit of the report.
Press * to continue.
CANCEL
1st 00 2nd 00
Enter the first digit of the Cancel report. Press *. Enter the second digit of the report.
Press * to continue.
PRGR TMPR
1st 00 2nd 00
Enter the first digit of the Program Tamper report. Press *. Enter the second digit of the report.
Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.
SYSTEM GROUP #2?
1 = YES 0 = NO
To enter System Group #2 codes, press 1.
Press 0 to skip to the next main menu option. (SYSTEM GROUP #3)
STAY
1st 00 2nd 00
Enter the first digit of the Closing (Arm-STAY) report. Press *. Enter the second digit of the report.
Press * to continue.
TIME SET LOG
1st 00 2nd 00
Enter the first digit of the System Time Set, Event Log Reset reports. Press *. Enter the second digit of the report.
Press * to continue.
LOG 50, 90
1st 00 2nd 00
Enter the first digit of the Event Log 50%, 90% Full reports. Press *. Enter the second digit of the report.
Press * to continue.
LOG OVRFLW
1st 00 2nd 00
Enter the first digit of the Event Log Overflow report. Press *. Enter the second digit of the report.
Press * to continue.
EXIT ERR ZONE
1st 00 2nd 00
Enter the first digit of the Exit Error by Zone report. Press *. Enter the second digit of the report.
Press * to continue.
EXIT ERR USR
1st 00 2nd 00
Enter the first digit of the Exit Error by User report. Press *. Enter the second digit of the report.
Press * to continue.
RECNT CLS
1st 00 2nd 00
Enter the first digit of the Recent Close report. Press *. Enter the second digit of the report.
Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.
SYSTEM GROUP #3?
1 = YES 0 = NO
To enter System Group #3 codes, press 1.
Press 0 to skip to the next main menu option. (SYSTEM GROUP #4)
EARLY OPEN
1st 00 2nd 00
Enter the first digit of the Early Opening report. Press *. Enter the second digit of the report.
Press * to continue.
EARLY CLOSE
1st 00 2nd 00
Enter the first digit of the Early Close report. Press *. Enter the second digit of the report.
Press * to continue.
LATE OPEN
1st 00 2nd 00
Enter the first digit of the Late Opening report. Press *. Enter the second digit of the report.
Press * to continue.
LATE CLOSE
1st 00 2nd 00
Enter the first digit of the Late Close report. Press *. Enter the second digit of the report.
Press * to continue.
FAILED OPEN
1st 00 2nd 00
Enter the first digit of the Failed to Open report. Press *. Enter the second digit of the report.
Press * to continue.
FAILED CLOSE
1st 00 2nd 00
Enter the first digit of the Failed to Close report. Press *. Enter the second digit of the report.
Press * to continue.
AUTOARM FAIL
1st 00 2nd 00
Enter the first digit of the Auto-Arm Failed report. Press *. Enter the second digit of the report.
Press * to continue.
SCHED CHANGE
1st 00 2nd 00
Enter the first digit of the Schedule Change report. Press *. Enter the second digit of the report.
Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.
SYSTEM GROUP #4?
1 = YES 0 = NO
To enter System Group #4 codes, press 1.
Press 0 to go to the Quit Menu Prompt.
WALK TEST START
1st 00 2nd 00
Enter the first digit of the Walk-Test Start report. Press *. Enter the second digit of the report.
Press * to continue.
WALK TEST END
1st 00 2nd 00
Enter the first digit of the Walk-Test End report. Press *. Enter the second digit of the report.
Press * to continue.
OFF NORMAL
1st 00 2nd 00
Enter the first digit of the Off-Normal report. Press *. Enter the second digit of the report.
Press * to continue.
QUIT REPORT MENU
1 = YES 0 = NO
If you have completely finished entering report codes, press 1 to quit Report Code Programming. If you
wish to enter other system report codes, enter 0. Press * to continue.





"ALPHA PROG?" 0 = No for Next Menu (Device Programming)
1 = Yes enter Alpha Descriptions
"ZONE DESCRIP?" 0 = No (moves to Default Screen Programming"
1 = Yes
1. "ZN ??" Enter 01 to 64, 95, 96, 99 then *, 00 exits
2. "ZN 01 A" Enter then 8 to save and move to "Zone Descrip. ?"
"DEFAULT SCRN?"
(shows while disarmed)
0 = No (moves to Custom Word Programming"
1 = Yes
1."Default Scrn P?" Enter Partition to edit (1, 2, 3 etc) or 0 to quit
2."**Disarmed**"
    Ready to Arm
Enter new Default Screen
1
3
4
6
7
8
= Goes backwards through Alphabet/Characters
= Advances through Alphabet/Characters
= Moves Cursor to Left
= Moves Cursor to Right
= Inserts Space or Erases existing character
= Stores current message
3."Default Scrn P?" Enter another default screen or 0 to exit
"CUSTOM WORD?" 0 = No (moves to Partition Description Programming" <
1 = Yes
1. "Custom Word ?" Enter 01 to 20 for Custom Word 01 to 20, 00 quits)
2. "Custom Word" Enter new Custom Word
1
3
4
6
7
8
= Goes backwards through Alphabet/Characters
= Advances through Alphabet/Characters
= Moves Cursor to Left
= Moves Cursor to Right
= Inserts Space or Erases existing character
= Stores current Custom Word
3."Custom Word?" Enter next Custom Word or 00 to exit
"PART DESCRIPT?" 0 = No (moves back to Zone Descrip Programming"
1 = Yes
1. "Part Desc P ?" Enter Partition to edit (1, 2, 3 etc) or 0 to quit
2. "P 1" Enter new Partition Description
1
3
4
6
7
8
= Goes backwards through Alphabet/Characters
= Advances through Alphabet/Characters
= Moves Cursor to Left
= Moves Cursor to Right
= Inserts Space or Erases existing character
= Stores current Custom Word
3."Part Desc P?" Enter next Partition Description or 00 to exit
"EXIT EDIT MODE?" 0 = Moves back to "Zone Descrip ?" screen
1 = Exits to Program Mode





"DEVICE PROG?" 0 = No for next menu (Relay Programming)
1 = Yes enter Device Programming
Display Options
1. "Device Add (01 - 15) ?" Enter Device Address 01 to 15, 00 to quit
2. "Dev Type (00 - 05) ?" Select Device then * for next, # for previous
00
01
02
03
04
05
= Not Used
= 2-Line Alpha Console (6129)
= Fixed English Console (6128)
= RF Expander (5881L/M/H)
= Output Device (Relay etc)
= Voice Module
3."RF Expander House ID" Enter 01 to 31 then * to return to "Dev Add (01 - 15) ?"
(this appears if 03 selected)
3."Console Home Part (01 - 02)" Enter Partition 1, 2 etc then * for next, # for previous
(this appears if 01 or 02 selected)
4. "Console Sounder Opt" Enter Option then * to return to "Dev Add (01 - 15) ?"
00
01
02
03
= No Suppression
= Suppress Arm/Disarm & E/E Beeps
= Suppress Chime Mode Beeps only
= Suppress Arm/Disarm/E/E & Chime Beeps





"RELAY PROGRAM ?" 0 = No for next menu (Zone List Programming)
1 = Yes enter Relay Programming
(Under Construction)





"RELAY VOICE DESCRIPT?" 0 = No for next menu (Custom Index)
1 = Yes enter Relay Voice Description Programming
(Under Construction)





"CUSTOM INDEX?" 0 = No for start of 93 menu (Zone Programming)
1 = Yes enter Custom Index Programming
(Under Construction)





(Under Construction)





(Under Construction)





(Under Construction)