Vista-100 128 total codes, (002 to 128), any code can be a Master or Manager Code which can change other codes (Must be in the same partition)
You cannot pause more than 2 seconds while entering below commands or it won't work
Add Code 1. Enter Master Code + 8 (CODE)
2. Enter User Code location (3 digit location) + new code
3. Keypad will ask "Add New User? 0 = NO, 1 = YES", press 1
4. Keypad will ask "Authority Level ?"
1 = Master Code (perform all system functions in assigned partitions and can add/delete codes)
2 = Manager Code (perform all system functions in assigned partitions and can add/delete codes except for Master Code)
3 = Operator A (perform system functions in assigned partitions, but cannot add/delete codes)
4 = Operator B (perform system functions in its partitions, but cannot add/delete codes or bypass zones)
5 = Operator C (arm the system but can only disarm if the system was armed with this code) (Babysitter code)
6 = Duress/Hostage Code
5. Keypad will ask "RFButton?" Normally enter 0
6. Keypad will ask "Multi Access?"
0 to access one partition
1 to access other partitions
7. If step 6 is Yes keypad will ask "Global Arm?" if Yes code will arm all partitions
Erase Code 1. Enter Master or Manager Code + 8 (CODE)
2. Enter User Number (3 digit location)
3. Enter Master or Manager Code again
3. Keypad will say "Okay to Delete? 0 = NO, 1 = YES", press 1
4. Keypad will say "User Code Deleted"
Reprogram
Master Code
Installer Code + 8 + (3 digit location) + New Master Code (Keypad should beep)
View User Info 4 digit code + **, keypad will display Authority/Partition levels