Ademco Vista 100 Programming
Enter Program 5140 + 8 + 0 + 0 + 0 (Display should show 00)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)

All Zone programming is done by # 93 menu, Click to go to section
ZONE PROG?
SERIAL PROG?
REPORT CODE PRG?
ALPHA PROG?
DEVICE PROGR?
RELAY PROG?
RLY VOICE DESCR?
CUSTOM INDEX?
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) for next menu, 1 (Yes) to enter this menu
0 (No) moves back to start, 1 (Yes) to enter this menu

*00 Installer Code I_5_I_1_I_4_I_0_I
*08 Temporal Siren Pulse I_0_I 0 = No
1 = Yes
*09 Entry Delay I_0_I_2_I 00 to 15 x15 seconds (Partition-Specific)
*10 Exit Delay 1 I_0_I_3_I 00 to 15 x15 seconds (Partition-Specific)
*11 Entry Delay 2 I_0_I_6_I 00 to 15 x15 seconds (Partition-Specific)
*12 Exit Delay 2 I_0_I_8_I 00 to 15 x15 seconds (Partition-Specific)
*13 Bell 1 Timeout I_0_I_4_I 00 to 15 x2 minutes (Partition-Specific)
*15 Keyswitch Assignment I_0_I 0 = Keyswitch Disabled
1 = Partition 1
to
8 = Partition 8
9 = Silence Bell if Fire Present
*16 Bell 1 Arming Ding I_0_I 0 = Disable (Partition-Specific)
1 = Enable
*17 AC Loss Keypad Sounding I_1_I 0 = No
1 = Yes
*19 AC Randomize I_2_I 0 = No
1 = Randomize 10 - 40 minutes
2 = Randomize 6 - 12 Hours
*20 VIP Module Phone Code I_0_I_0_I I_1_I_1_I 1st Digit = 01 to 09
2nd Digit = 11 for * 12 for #
*22 Keypad Panic Enable I_1_I I_1_I I_1_I 0 = Disabled (Partition-Specific)
1st Digit = Zone 995 1 = Enabled
2nd Digit = Zone 996
3rd Digit = Zone 999
*23 Multiple Alarms I_1_I 0 = No (Partition-Specific)
1 = Yes
*24 Ignore Exp Zone Tamper I_0_I 0 = Enable Tamper for RF & RPM
1 = Ignore Zone Tampers
*25 LRR Burg Trigr ZType 8 I_0_I 0 = No
1 = Yes
*26 Intelligent Test Reporting I_0_I 0 = No
1 = No Report if other Reports Sent
*27 Test Report Interval I_0_I_2_I_4_I 000 = Disabled
001 to 999 Hours
*28 Power up in Prev State I_1_I 0 = No
1 = Yes
*29 Quick Arm I_1_I 0 = No (Partition-Specific)
1 = Yes
*30 Main Dialer Tone Dialing I_1_I 0 = No
1 = Yes
*31 PABX Access Code I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I
*32 Primary Account Number I_0_I_?_I I_0_I_?_I I_0_I_?_I I_0_I_?_I (2 digit entries) (Partition-Specific)
Hex B = 11, C = 12, D = 13, E = 14, F = 15
*33 Primary Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause
*34 Secondary Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*35 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I_ _I_ _I_ _I
*36 CSID Number I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I
(15's Default CSID to Factory)
*37 Download Cmnds Enable I_1_I Dialer Shutdown
I_1_I System Shutdown
I_0_I Not Used
I_1_I Remote Bypass
I_1_I Remote Disarm
I_1_I Remote Arm
I_1_I Upload Prgrmming
I_1_I Dwnld Prgrmming
0 = No
1 = Yes
*38 Prevent Zone Bypass I_0_I_0_I_0_I 000 = All zones bypassable (Partition-Specific)
001 to 087 = Zone 01 to 32
*39 O/C Report for Installer I_0_I 0 = No (Partition-Specific)
1 = Yes
*40 O/C Report for Keyswitch I_0_I 0 = No
1 = Yes
*41 Nrmlly Clsd Zones 3 to 8 I_0_I 0 = EOL Resistors
1 = Normally Closed
*42 Dial Tone Pause I_0_I 0 = 5 seconds
1 = 11 seconds
2 = 30 seconds
*43 Dial Tone Detection I_0_I 0 = Pause then Dial
1 = Wait for True Dial Tone
*44 Ring Detection Count I_1_I_5_I 15 = Answering Machine
*45 Primary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*46 Low Speed Frmt (Prime) I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics
*47 Secondary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express
*48 Low Speed Format 2nd I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics
*49 Checksum Verify
I_0_I
Pri
I_0_I
Sec
0 = No
1 = Yes
*50 Sescoa Radionics Select I_0_I 0 = Radionics
1 = Sescoa
*51 Dual Reporting I_0_I 0 = No
1 = Yes
*52 Stndrd/Expanded Report
       for Primary
I_0_I Alarm/Fire Supv
I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat
0 = Standard
1 = Expanded
*53 Stndrd/Expanded Report
       for Secondary
I_0_I Alarm/Fire Supv
I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat
0 = Standard
1 = Expanded
*79 Restore Enable Zone Types 1 to 8
       I_0_I Zone Type 1 (Entry/Exit 1)
       I_0_I Zone Type 2 (Entry Exit 2)
       I_0_I Zone Type 3 (Perimeter)
       I_0_I Zone Type 4 (Interior Follower)
       I_0_I Zone Type 5 (Day/Night)
       I_0_I Zone Type 6 (24 Hour Silent)
       I_0_I Zone Type 7 (24 Hour Audible)
       I_0_I Zone Type 8 (24 Hour Auxiliary)
0 = No Restoral Report
1 = Restoral Report
*80 Restore Enable Zone Types 9 and 10
       I_0_I Zone Type 9 (Fire w/o verify)
       I_0_I Zone Type 10 (Interior w/Delay)
0 = No Restoral Report
1 = Restoral Report
*83 First Test Report Time    I_0_I_0_I I_1_I_2_I I_0_I_0_I    00 in all boxes = instant.
Day Hour Minutes Day 01 = Monday
*84 Swinger Shutdown I_0_I_4_I 00 = Disabled (Partition-Specific)
01 to 15 = 01 to 15 Alarms
*85 Enable Dialer Reports I_1_I Zone 995
I_1_I Zone 996
I_1_I Zone 999
I_1_I Duress
0 = Disable (Partition-Specific) 1 = Enable
*87 Entry Warning I_1_I 0 = 3 Beeps (Partition-Specific)
1 = Continuous
*88 Burg Alarm Comm Delay I_0_I 0 = No Delay (Partition-Specific)
1 = 16 seconds
*89 Restore Report Timing I_0_I 0 = Instant
1 = At Bell Timeout
2 = At Disarm
*90 Secondary Account Number    I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I (2 digit entries)
Hex B = 11, C = 12, D = 13, E = 14, F = 15

To access Upper programming press *94, to return to lower programming press *99
the 1 isn't part of location, to go to a Upper program location press * + 2-digits

1*17 Common Lobby Partition I_0_I 0 = Disabled
1 = Partition 1
to
8 = Partition 8
1*18 Affects Lobby I_0_I 0 = Does Not Affect Lobby (Partition-Specific)
1 = Affects Lobby
1*19 Arms Lobby I_0_I 0 = Does Not Arm Lobby (Partition-Specific)
1 = Arms Lobby
1*20 Exit Error Logic I_0_I 0 = No
1 = Bypass E/E & Interior Zones
faulted after Exit Delay
1*21 Exit Delay Reset I_0_I 0 = No
1 = Resets Exit Delay to 60 seconds
after Zone is Closed
1*22 Cross-Zoning Pair One I_ _I_ _I_ _I I_ _I_ _I_ _I
1*23 Cross-Zoning Pair TwoI_ _I_ _I_ _I I_ _I_ _I_ _I
1*24 Cross-Zoning Pair Three I_ _I_ _I_ _I I_ _I_ _I_ _I
1*25 Cross-Zoning Pair Four I_ _I_ _I_ _I I_ _I_ _I_ _I
1*28 RF TX Low Battery Sound I_0_I 0 = When Disarmed
1 = Immediate
1*29 RF TX Low Batt Report I_0_I 0 = Disable
1 = Enable
1*30 RF RCVR Check-In I_0_I_6_I 02 to 15 x2 Hours
1*31 RF xmitter Check-In I_1_I_2_I 02 to 15 x2 Hours
1*32 RF Receiver Type I_0_I 0 = Disable
1 = 4281
2 = 5881
1*33 Tone w/ Rotory Backup I_1_I 0 = Disable
1 = Enable
1*34 Comm Split Report I_0_I 0 = No
1 = Alarms to Primary, others Sec.
2 = O/C/Test Secondary, others Pri.
3 = Fire alarms/troubles Primary, all Sec.
1*42 Call Waiting Defeat I_0_I 0 = No
1 = Yes
1*43 Perm Keypad Backlight I_1_I 0 = No (Partition-Specific)
1 = Yes
1*44 Wireless Keypad Tamper I_0_I 0 = Disable
1 = Lockout RF if tamper detected
1*45 - Exit Delay Sounder I_0_I 1 = Enable (Partition-Specific)
0 = Disable
1*47 Chime on Bell 1 I_0_I 0 = Disable (Partition-Specific)
1 = Enable
1*48 Wireless Keypad Part I_0_I 0 = Disable
1 = Partition 1
to
8 = Partition 8
1*49 Suppress TX Sprv Sound I_1_I 0 = Enable
1 = Disable
1*52 Send Cancel I_0_I 0 = No Restriction (Partition-Specific)
1 = Within Bell Timeout
1*53 Download Callback I_1_I 0 = Callback Required
1 = No Callback
1*57 5800RF Global Arm I_0_I 0 = Disable
1 = Enable
1*58 5800RF Force Arm I_0_I 0 = Disable
1 = Enable
1*60 Zone 5 Audio Alarm I_0_I 0 = Disable
1 = Enable
1*70 Event Log Types I_1_I Alarm
I_1_I Check
I_1_I Bypass
I_1_I O/C
I_1_I System
I_1_I Test Rpt
0 = Disable Logging
1 = Enable Logging
1*71 12/24 Hour Time StampI_1_I 0 = 12 Hour
1 = 24 Hour (Military)
1*72 Log Printer On-line Mode I_0_I 0 = Disable
1 = Enable
1*73 Printer Baud Rate I_0_I 0 = 1200 Baud
1 = 300 Baud
1*74 Relay Timeout XXX Min. I_0_I_0_I_0_I 0 to 127 x2 Minutes
Enter relay timeout desired for #80 Menu Mode
time-driven event relay command
numbers "04/09" and #93 Menu Mode
Output Programming output command "56."
1*75 Relay Timeout YYY Sec. I_0_I_0_I_0_I 0 to 127 Seconds
Enter relay timeout desired for #80 Menu Mode
time-driven event relay command
numbers "05/10" and #93 Menu Mode
Output Programming output command "57."
1*76 Access Control Relay I_0_I_0_I 00 to 16 (Partition-Specific)
Relay will be pulsed for 2 seconds
whenever code + [0] is pressed.

To access Upper programming press *94, to return to lower programming press *99
the 2 isn't part of location, to go to a Upper program location press * + 2-digits

2*00 Number of Partitions I_1_I 1 = 1 Partition
to
8 = 8 Partitions
2*01 DST Start/End Month I_0_I_3_I I_1_I_1_I 00, 00 = Disable DST
Start End 01 - 12 = Month
2*02 DST Start/End Weekend
I_2_I
Start
I_1_I
End
1 to 7
1 = First
2 = Second
3 = Third
4 = Fourth
5 = Last
6 = Next to Last
7 = Third from Last
2*05 Auto-Arm Delay I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 14 x4 Minutes
15 = No Auto-Arm
2*06 Auto-Arm Warning Period I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 15 Minutes
2*07 Auto-Disarm Delay I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 14 x4 Minutes
15 = No Auto-Disarm
2*08 Force Arm for Auto-Arm I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*09 O/C Reports by Exception I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*10 Disarming Only During
    Arming/Disarming Windows
I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*11 Disarming Outside Window
    if Alarm Occurs
I_0_I 0 = Disable (Only used if 2*10 is a 1)
1 = Enable
2*18 Enable Go To for Partition I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*19 Use Partition Descriptors I_0_I 0 = Disable
1 = Enable
2*20 Enable J2 Triggers for PartI_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*21 Enable Supervision Pulses
    For LRR Trigger Outputs
I_0_I Fire 0 = Disable
I_0_I Burglary 1 = Enable
I_0_I Silent panic/Duress
2*22 Display Fire Alarms of
    Other Partitions
I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*23 Display Burg & Panics
   of Other Partitions
I_0_I 0 = Disable (Partition-Specific)
1 = Enable
2*24 Display Troubles of
   Other Partitions
I_0_I 0 = Disable (Partition-Specific)
1 = Enable
To access Upper programming press *94, to return to lower programming press *99
the 3 isn't part of location, to go to a Upper program location press * + 2-digits
3*00 Check or Trouble Display I_0_I 0 = Check Displayed
1 = Trouble Displayed
3*13 Supv Open & Short I_0_I 0 = Supv. on short/trouble on open
1 = Supv. on short or open
3*14 Waterflow Silence Option I_0_I 0 = Silence on Code + 1
1 = Silence on restoral
3*15 Alarm Bell Sound I_0_I Bell 1
I_0_I Bell 2
0 = Pulsed
1 = Steady
3*16 Zone Types 17 & 18 Delay I_0_I_0_I 00 to 15 x2 seconds
(Waterflow & Fire Supervision)
3*17 Zone 6 Alt Func (Tamper) I_0_I_0_I 0 = Disabled
1 = Enabled
3*18 ZT 17 & 18 Ext Delay I_0_I 0 = Use Delay in 3*16
1 = Multiply 3*16 delay by 4
3*19 AUX in Alt Func I_0_I 0 = Pins 5 & 9 function per 3*20
1 = Pins 5 & 9 as printer RXD & DTR
3*20 Trigger Outputs Selection I_0_I 0 = Lorra Full Connection
1 = Lorra Limited Connection/Keyswitch
2 = Lorra Fire Connection & 5140LED
3*21 Max # of Dialer Retries I_8_I 1 to 8 attempts
3*30 Dialer Selection I_1_I Main
I_1_I Backup
0 = Disabled
1 = Enabled
3*31 Backup Dialer Tone/Rotary I_0_I 0 = Rotary
1 = Touch Tone
3*50 Zone Type Restore Enable
    For Zone Types 16 to 18
    16 = Fire w/Verification
    17 = Fire Water Flow
    18 = Fire Supervisory
I_1_I Zone Type 16
I_1_I Zone Type 17
I_1_I Zone Type 18
0 = Disabled
1 = Enabled
3*57 Bell 2/Aux Relay Arm Ding I_0_I Bell 2
I_0_I Aux
0 = Disabled (Partition-Specific)
1 = Enabled
3*58 Bell 2/Aux Relay AC Loss I_0_I Bell 2
I_0_I Aux
0 = Disabled (Partition-Specific)
1 = Enabled
3*59 Bell 2/Aux Relay Chime Annunciation (Partition-Specific)
I_0_I Bell 2
I_0_I Aux
0 = Disabled
1 = Enabled
3*60 Bell 2/Aux Relay Timeout I_0_I_0_I Bell 2
I_0_I_0_I Aux
0 = Disabled (Partition-Specific)
1 = Enabled
3*61 Aux Relay Function I_0_I 0 = Trouble/Supervisory
1 = Alarm/Silenced by Code + OFF
2 = Smoke Detector Reset
3 = Battery Save
4 = Alarm, Silenced by
Code + # + 67
3*82 Enable Features on P1 I_1_I 0 = Disable
1 = Enable
(Away, Stay, Max, Test, Instant, Chime Functions)
3*85 Enable Fire & System Zone Bypass
I_1_I 0 = Not Enabled
1 = Only Installer can Bypass
2 = Only Installer & Master can Bypass