All wireless is Standard Ademco 5800 sensors, old Apex Wireless cannot be used |
Enter Program | Press 9173 (Default) |
Enter Data | Enter 4-digit location + New value |
Clear Location | 4-digit location + A |
Read Location | 4-digit location + H, keypad will speak what is in location |
Exit Program | 9899 keypad will say "Exit Program Mode" |
Defaulting | Press SW1 until 1 beep defaults Master Code
until 5 beeps defaults Installer Code
until 10 beeps defaults Panel |
|
|
Zone Programming |
|
1. Enter 9940 |
2. "Enter 2-Digit Zone Number" | (01 to 96) |
3. "Enter 3-Digit Zone Type" |
Exterior Instant | = 000 | Silent Panic | = 008 |
Exterior Delay 1 | = 001 | Emergency | = 009 |
Exterior Delay 2 | = 002 | Follower | = 010 |
Interior Instant | = 003 | Aux Type 1 | = 011 |
Interior Delay 1 | = 004 | Aux Type 2 | = 012 |
Interior Delay 2 | = 005 | Day Zone | = 013 |
Fire | = 006 | Step Arming | = 014 |
Panic | = 007 | Button Device Type | = 015 |
| Disable Zone | = 255 |
|
3. "Enter 3-Digit Zone Options 1" | 000 = No Option Below Selected (Default)
016 = Report to Central Station
064 = Display Open at Keypad
080 = Both options
000 = Neither Option |
4. "Enter 3-Digit Zone Option 2" | 000 = No Option Below Selected (Default)
001 = Partition 1
002 = Partition 2
003 = Partition 3
004 = Partition 4 (Add together if needed)
005 = Partition 5
006 = Partition 6
007 = Partition 7
008 = Partition 8
016 = Supress Speech/Beeps for Monitor
032 = Supress OPEN from being Spoken
064 = Supress Siren on Activation |
5. "Enter Enter Device Type" | V (HARDWIRED) V
000 = 16 Hardwired Zone Input (on Main Board)
001 = 16-Zone Expansion Board
002 = 2-Wire Smoke Loop
021 = Phone Line Monitor
V (WIRELESS) V
025 = 5814 Mini Door Transmitter
003 = 5616 Wireless Door/Window Sensor
004 = 5816 Temp Low Temp Wireless Transmitter
005 = 5817 3-Input Wireless Alarm Transmitter (3 Loop Sensor)
006 = 5818 Recessed Door Wireless Transmitter
007 = 5819 3-Input Shock Wireless Transmitter
024 = 5819WHS Shock Sensor
012 = 5849 Wireless Shock / Glass Detector
011 = 5890 Wireless Motion Transmitter
018 = 5806 Wireless Smoke Detector
019 = 5807 Wireless Smoke Detector
020 = 5808 Smoke Detector
027 = 5809 Smoke Detector
V (BUTTON TYPE) V Each button uses 1 zone
008 = 5801 4-Button Portable Keyfob (Zone Type must be 015)
016 = 5802CP 1-Button Portable Panic (Zone Type must be 015)
009 = 5802MN 1-Button Portable Panic (Zone Type must be 015)
026 = 5802MN2 2-Button Portable Panic (Zone Type must be 015)
010 = 5804 4-Button Keyfob (Zone Type must be 015)
V (ZONE INPUT DEVICES) V
013 = Keypad Alert Activations (Zone Type must be 015)
015 = Local telephone 5 Zero Activation
016 = Loss of Phone Line Activation
017 = 5802CP 1 Button Portable Panic (Zone Type must be 015)
020 = X-10 ON/OFF Command
022 = TS-16 Temperature Sensor |
6. Press F2 if above values are correct, press H to start over |
7. System will ask Loop Number, enter 01 to 16 then press F2
For Hardwired devices enter Loop used on circuit board
For Wireless devices enter Loop used on Transmitter
| 8. System will prompt for next Sensor or Serial Number of current device, enter serial from sticker |
9. If wireless Keyfob enter function of key
000 = Speak Time
005 = Speak Status
017 = Step Arming (press button for Stay, again for Away)
018 = Armed to Away
019 = Armed to Home
020 = Disarm
024 = Output Control 1
039 = Output Control 16 |
|
|
System Access Codes |
|
PC Access Code | Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0495 010 (*)
0496 010 (*)
0497 001
0498 002 |
Program Mode Access Code | Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0769 009
0770 001
0771 007
0772 003 |
Local Phone Access Code | Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0784 010 (*)
0785 011 (#)
0786 255 (N/A)
0787 255 (N/A) |
Secured Callback Access Code | Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0789 002
0790 005
0791 008
0792 000 |
|
|
Downloading Options |
|
Answering Machine Override Digit | Location
0774 | Default
011 (#) |
Number of Rings before Answering | Location
0458 | Default
010 |
|
|
System Option Automated Programming |
|
| Locations |
Clear event memory log and long term memory | 9898 |
Enter Phone # for automatic download (From system Keypad only) | 9904 |
Enter Account # for automatic download (From system Keypad only | 9909 |
Speak automatic download Phone # | 9914 |
Speak automatic download account # | 9919 |
Initiate direct connect computer programming | 9952 |
Initiate unattended programming download | 9953 |
Initiate unattended event memory log upload | 9954 |
Speak software revision number | 9990 |
Set time/date (HH-Hour, MM-Minute, W-Day of week, MM-Month, DD-Day, YY-Year) | 9991 |
Set automatic arm/disarm times (Not permitted in a UL installation) | 9993 |
Speak time and date | 9996 |
Set automatic Event Memory Log upload time | 9997 |
|
|
System Options 1 |
|
Options - Enter Total | Location | Value |
Automatic time control of remote channels in AWAY mode | 002 |
Disarm before rearm | | 004 |
Mute external Speaker (ext driver -off, int- adjustable) | 008 |
Access code before arm | | 016 |
Speak pre-alarm instead of tone | | 032 |
3 digit disarm code | | 064 |
Echo system status with 1st digit of a user code | | 128 |
|
Default | 0130 | 164 |
|
|
System Options 2 |
|
Options - Enter Total | Location | Value |
Automatic "force arm" (no second key press) | | 004 |
No exterior instant exit delay | | 008 |
No entry delay for Exterior Delay 1 in HOME mode | 016 |
Auto 96 hr clear long term memory and event memory log | 032 |
Zone trouble = zone activation when armed | 064 |
|
Default | 0131 | 000 |
|
|
System Options 3 |
|
Options - Enter Total | Location | Value |
Speak time remaining and end of exit delay | | 001 |
Track activations and record in Long Term Memory | 002 |
Voice driver | | 004 |
Enable split arming (Not permitted in a UL installation) | 008 |
Echo local phone speech to inside speaker | | 016 |
Enable night mode | | 032 |
Enable two-way voice call back (Do not use on a UL install) | 064 |
|
Default | 0132 | 039 |
|
|
System Options 4 |
|
Options - Enter Total | Location | Value |
Turn off Pre-alarm System trigger at disarm or alert | 064 |
Suppress Dialer during 2-way callback wait period | | 128 |
|
Default | 0133 | 000 |
|
|
System Options 5 |
|
Options - Enter Total | Location | Value |
Speak auxiliary zone type | | 001 |
Speak status immediately after local phone access | | 002 |
Silence inside speaker in Home mode | | 004 |
Speak zone description in Extended Monitor | | 008 |
Disable force arming | | 064 |
|
Default | 0134 | 009 |
|
|
System Options 6 |
|
Options - Enter Total | Location | Value |
Speak remote control menu (Do Not do on a UL installation) | 001 |
Speak time and date when time is requested | | 002 |
Speak temp when time is requested (See "Using a TS-16") | 004 |
Enable answer service override callback | | 008 |
|
Default | 0135 | 003 |
|
|
System Times |
|
System Time Options | Time Increment | Location | Default |
Entry delay 1 | Seconds | 0136 | 020 |
Entry delay 2 | Seconds | 0137 | 020 |
Exit delay (Not to exceed 60 seconds in a UL installation) | Seconds | 0138 | 030 |
Alarm cut off and reset | Minutes | 0139 | 005 |
Duration between fire chirps | Seconds | 0142 | 000 |
Duration for recognition of AC power loss | Minutes | 0153 | 001 |
Duration between spoken "Pre-alarm" cycles (000 = 3 seconds) | Seconds | 0156 | 000 |
Fire siren tone duration before speech | Seconds | 0158 | 005 |
Burglary siren tone duration before speech | Seconds | 0159 | 005 |
Fire cut off and reset (Not permitted in a UL installation) | Minutes | 0157 | 005 |
Number of 4 second samples to determine loss of phone line | | 0456 | 006 |
Number of activations for swinger shutdown (000 Disables) | | 0176 | 000 |
Time frame for swinger shutdown to occur | Hours | 0177 | 024 |
Time frame for "answer after 1st ring" when
answering service override is activated | Seconds | 0470 | 025 |
|
|
Bypass Options |
|
Option - Enter Total | Location | Value |
Open zones automatically bypassed at "force arm" | | 001 |
Zones bypassed by "force arm" auto unbypassed at disarm | 002 |
Unbypass all bypassed zones automatically at disarm | | 004 |
|
Default | 0243 | 000 |
|
|
Phone Access Options |
|
Option - Enter Total | Location | Default |
Number of rings for pickup (minimum 002, 000 disables) | 0458 | 010 |
Inactivity before auto hang up while user phone access | 0780 | 015 |
Inactivity before auto hang up/exit programming by phone | 0781 | 060 |
|
|
Communicator Programming |
|
| Location |
Enter Phone #1 (Press H or # twice when finished) | 9900 |
Enter Phone #2 (Press H or # twice when finished) | 9901 |
Enter Account #1 | 9905 |
Enter Account #2 | 9906 |
Speak Phone #1 | 9910 |
Speak Phone #2 | 9911 |
Speak Account #1 | 9915 |
Speak Account #2 | 9916 |
Set Fail to Open/Close times | 9994 |
Set Communicator test times | 9995 |
Echo communicator activity through inside speaker | 9960 |
|
|
Communicator Options |
|
| Location | Default |
Delay before dialing after activation Phone #1 (000-disables) | 0437 | 002 |
Delay before dialing after activation Phone #2 (000-disables) | 0438 | 002 |
Off-hook time during listen-in before auto hang-up (000-256 sec) | 0453 | 120 |
Central Station handshake wait period | 0455 | 025 |
Two-way callback from central station wait period | 0461 | 002 |
Voice only and two-way callback wait period for a valid code | 0465 | 060 |
Maximum number of dialing attempts Phone #1 | 0449 | 008 |
Maximum number of dialing attempts Phone #2 | 0450 | 008 |
Touch tone (000) or pulse (001) dialing | 0454 | 000 |
Enable cellular backup (ignore dial tone) (001 - enabled) | 0466 | 000 |
|
|
Reporting Format Enter total Value |
|
Silent Knight Slow | | 000 |
Silent Knight Fast | | 001 |
Sescoa Fast (Radionics) | | 002 |
Multiple Reports / Connection | | 008 |
Voice Only | | 032 |
|
| Location | Add above |
Phone #1 Default | 0441 | 010 |
Phone #2 Default | 0443 | 010 |
|
|
Reporting Options Enter total Value |
|
3/1 | | 001 |
4/2 extended w/ zone ID | | 002 |
4/1/1 | | 004 |
Ademco Contact-ID (4 digit) | | 008 |
|
| Location | Add Above |
Phone #1 Default | 0442 | 008 |
Phone #2 Default | 0444 | 008 |
|
|
Two-Way Voice Options |
|
Voice Only Options - Enter total | | Value |
One Digit Access | | 016 |
Full User Code Access | | 032 |
The 0 digit exits to keypad mode | | 128 |
Two Way Callback Options |
One Digit Access | | 001 |
Full User Code Access | | 002 |
The 0 digit exits to keypad mode | | 008 |
|
| Location | Total |
Default | 0464 | 008 |
|
|
Two-Way Digit Assignments |
|
| Location | Default |
0 Exit 2-way by going to keypad mode or hanging up | 0223 | 000 |
1 Microphone #1 On | 0224 | 001 |
2 Microphone #2 On | 0225 | 002 |
3 Microphone #3 On | 0226 | 003 |
4 Microphone #1 Off | 0227 | 004 |
5 Microphone #2 Off | 0228 | 005 |
6 Microphone #3 Off | 0229 | 006 |
7 High microphone sensitivity | 0230 | 007 |
8 Normal microphone sensitivity | 0231 | 008 |
9 All microphones on | 0232 | 009 |
* Listen | 0233 | 010 |
# Talk | 0234 | 011 |
Rearrange Keypad phone digits (001 to change from default) | 0222 | 000 |
|
|
Automatic Communicator Testing |
|
Choose to Report Daily, Weekly, or Monthly | Location | Value |
Report Daily | 0166 | 000 |
Report Weekly | | 064 |
Sunday | | 001 |
Monday | | 002 |
Tuesday | | 003 |
Wednesday | | 004 |
Thursday | | 005 |
Friday | | 006 |
Saturday | | 007 |
Enter Total (Example is Report on every Sunday) | 0166 | 065 |
Report Monthly | | 128 |
Add the day of the month to use (valid days are 1-31) | | 001 |
|
Default | 0166 | 129 |
|
|
Report Codes |
|
Dialer Options |
001 | = Dial Phone 1 |
002 | = Dial Phone 2 |
004 | = Enable 2-Way Voice |
008 | = Dial Alternate Number if 1st choice fails |
128 | = Record this into Event Memory Log |
|
For 2-way use 133 ??? Add together for value to program into Dialer Options
For no 2-way use 129 |
Report Type | Location | Value |
Exterior Instant | Central Station Report Code
Dialer Option | 0337
0387 | 003
133 |
Exterior Delay 1 | Central Station Report Code
Dialer Option | 0338
0388 | 003
133 |
Exterior Delay 2 | Central Station Report Code
Dialer Option | 0339
0389 | 003
133 |
Interior Instant | Central Station Report Code
Dialer Option | 0340
0390 | 004
133 |
Interior Delay 1 | Central Station Report Code
Dialer Option | 0341
0391 | 004
133 |
Interior Delay 2 | Central Station Report Code
Dialer Option | 0342
0392 | 004
133 |
Fire | Central Station Report Code
Dialer Option | 0343
0393 | 001
133 |
Panic | Central Station Report Code
Dialer Option | 0344
0394 | 002 133 |
Silent Panic | Central Station Report Code
Dialer Option | 0345
0395 | 002
133 |
Emergency | Central Station Report Code
Dialer Option | 0346
0396 | 005
133 |
Follower | Central Station Report Code
Dialer Option | 0347
0397 | 004
133 |
Auxiliary Zone Type | Central Station Report Code
Dialer Option | 0348
0398 | 005
133 |
Duress Disarm Silent | Central Station Report Code
Dialer Option | 0349
0399 | 002
133 |
Duress When Not Armed | Central Station Report Code
Dialer Option | 0350
0400 | 002
133 |
Zone Restore After Alarm | Central Station Report Code
Dialer Option | 0351
0401 | 009
129 |
Transmitter Low Battery | Central Station Report Code
Dialer Option | 0352
0402 | 006
129 |
Transmitter Battery Restore | Central Station Report Code
Dialer Option | 0353
0403 | 009
129 |
Zone Trouble | Central Station Report Code
Dialer Option | 0354
0404 | 008
133 |
Zone Trouble Restore | Central Station Report Code
Dialer Option | 0355
0405 | 009
133 |
High Current Trouble | Central Station Report Code
Dialer Option | 0356
0406 | 008
133 |
High Current Restore | Central Station Report Code
Dialer Option | 0357
0407 | 009
129 |
Phone Line Restore | Central Station Report Code
Dialer Option | 0358
0408 | 009
128 |
Open (Disarm) | Central Station Report Code
Dialer Option | 0359
0409 | 011
128 |
Open (Disarm) After Alarm | Central Station Report Code
Dialer Option | 0360
0410 | 011
128 |
Close (Arm) | Central Station Report Code
Dialer Option | 0361
0411 | 012
128 |
Force Arm | Central Station Report Code
Dialer Option | 0362
0412 | 012
128 |
Control Low Battery | Central Station Report Code
Dialer Option | 0363
0413 | 008
129 |
Control Battery Restore | Central Station Report Code
Dialer Option | 0364
0414 | 009
129 |
AC Fail | Central Station Report Code
Dialer Option | 0365
0415 | 008
129 |
AC Restore | Central Station Report Code
Dialer Option | 0366
0416 | 009
128 |
User Communicator Test | Central Station Report Code
Dialer Option | 0367
0417 | 007
129 |
Auto Communicator Test | Central Station Report Code
Dialer Option | 0368
0418 | 007
128 |
Cancel | Central Station Report Code
Dialer Option | 0369
0419 | 000
133 |
Zone Bypass | Central Station Report Code
Dialer Option | 0370
0420 | 013
128 |
Zone Unbypass | Central Station Report Code
Dialer Option | 0371
0421 | 014
128 |
Day Zone Trouble | Central Station Report Code
Dialer Option | 0372
0422 | 008
128 |
Day Zone Trouble Restore | Central Station Report Code
Dialer Option | 0373
0423 | 009
128 |
Upload/Download Attempt | Central Station Report Code
Dialer Option | 0374
0424 | 015
129 |
Program Mode Entry | Central Station Report Code
Dialer Option | 0375
0425 | 015
128 |
Fail to Open | Central Station Report Code
Dialer Option | 0376
0426 | 011
128 |
Fail to Close | Central Station Report Code
Dialer Option | 0377
0427 | 012
128 |
Zone Expander Trouble | Central Station Report Code
Dialer Option | 0378
0428 | 008
128 |
Zone Expander Trble Restore | Central Station Report Code
Dialer Option | 0379
0429 | 009
128 |
Zone Open | Central Station Report Code
Dialer Option | 0380
0430 | 000
000 |
Zone Restore | Central Station Report Code
Dialer Option | 0381
0431 | 000
128 |
Tamper | Central Station Report Code
Dialer Option | 0382
0432 | 008
128 |
Tamper Restore | Central Station Report Code
Dialer Option | 0383
0433 | 009
128 |
Receiver Supervision Trouble | Central Station Report Code
Dialer Option | 0384
0434 | 008
128 |
Receiver Supervision Restore | Central Station Report Code
Dialer Option | 0385
0435 | 009
128 |
Number of retires when dialing | | 0246 | 008 |
|
|
Keypad Automated Programming Locations |
|
Option | Location |
Clear user codes 2-32 | 0000 |
Clear keypad status | 9897 |
Enter Zone / TS16 / Area description | 9920 |
|
Enter remote control channel description | 9921 |
Speak Zone / TS16 / Area description | 9930 |
Speak remote control channel description | 9931 |
Download Words to Keypad | 9965 |
Speak a selected word | 9999 |
|
|
Keypad Option |
|
Option | Value |
Display time in 24 hour format | 001 |
Default (standard time format | 000 |
|
|
Keypad Area Assignment |
|
Options - | Enter Total Value |
Area 1 | 001 |
Area 2 | 002 |
Area 3 | 004 |
Area 4 | 008 |
Area 5 | 016 |
Area 6 | 032 |
Area 7 | 064 |
Area 8 | 128 |
Default | 000 |
|
|
User Code + Digit Functions |
|
User Code + Options | Local phone/Keypads | Function | Remote Phone | Function |
Function for User Code + 1 | 0178 | 000 | 0775 | 015 |
Function for User Code + 2 | 0179 | 001 | 0776 | 001 |
Function for User Code + 3 | 0180 | 013 | 0777 | 013 |
Function for User Code + 4 | 0181 | 014 | 0778 | 014 |
Function for User Code + 5 | 0182 | 004 | 0779 | 005 |
User Code + 6 Smoke Power Reset
User Code + 7 Change User Codes
User Code + 8 Speak Alert Memory
User Code + 9 Bypass Mode
User Code + 0 Communicator Test |
|
|
Extended Monitor Times (seconds) |
|
System Time Options Time Increment | Location | Default |
Time extended monitor displayed on keypad (000-continuous) | 0236 | 030 |
Time between speech/beeps w/extended monitor active (000-disable) | 0237 | 005 |
|
|
Zone Types - |
|
Enter Total for Extended Monitor A | Location | Value |
Exterior instant | | 001 |
Exterior delay 1 | | 002 |
Exterior delay 2 | | 004 |
Interior instant | | 008 |
Interior delay 1 | | 016 |
Interior delay 2 | | 032 |
Follower | | 064 |
Auxiliary 1 and 2 | | 128 |
|
Default | 0238 | 001 |
|
|
Extended Monitor Zone Type Assignment |
|
Enter Total for Extended Monitor B | Location | Value |
Exterior instant | | 001 |
Exterior delay 1 | | 002 |
Exterior delay 2 | | 004 |
Interior instant | | 008 |
Interior delay 1 | | 016 |
Interior delay 2 | | 032 |
Follower | | 064 |
Auxiliary 1 and 2 | | 128 |
|
Default | 0239 | 007
|
|